# Test for nrf24l01p lowlevel functions
## About
This is a small test application to see how the lowlevel-driver functions of
the proprietary nrf24l01p-transceiver work. These functions consist of general
SPI and GPIO commands, which abstract the driver-functions from the used board.
## Predefined pin mapping
Please compare the `tests/driver_nrf24l01p_lowlevel/Makefile` for predefined
pin-mappings on different boards. (In addition, you also need to connect to 3V
and GND)
## Usage
You should be presented with the RIOT shell, providing you with commands to
initialize the transceiver (command: `it`), sending one packet (command:
`send`) or read out and print all registers of the transceiver as binary values
(command: `prgs`).
### Procedure
* take two boards and connect a transceiver to each
(it should be also possible to use one board with different SPI-ports)
* depending on your board, you'll maybe also need to connect a UART/tty converter
* build and flash the test-program to each
* open a terminal (e.g. pyterm) for each
* if possible, reset the board by using the reset-button. You'll see "_Welcome to RIOT_" etc.
* type `help` to see the description of the commands
* initialize both with `it`
* with one board, send a packet by typing `send`
* in the next step you can also use `send` to send data in the other direction
* now you can use send on both boards/transceivers to send messages between them
## Expected Results
After you did all steps described above, you should see that a 32 Byte sequence
(numbers from 32...1) has been transferred from one device to the other. This
sequence is printed out from the receiver after the receive interrupt occurred
and the receive-procedure has been made.
After initialization (`it`) you should see the following output:
```
> it
Init Transceiver
Registering nrf24l01p_rx_handler thread...
################## Print Registers ###################
REG_CONFIG:
0x0 returned: 00111111
REG_EN_AA:
0x1 returned: 00000001
REG_EN_RXADDR:
0x2 returned: 00000011
REG_SETUP_AW:
0x3 returned: 00000011
REG_SETUP_RETR:
0x4 returned: 00101111
REG_RF_CH:
0x5 returned: 00000101
REG_RF_SETUP:
0x6 returned: 00100111
REG_STATUS:
0x7 returned: 00001110
REG_OBSERVE_TX:
0x8 returned: 00000000
REG_RPD:
0x9 returned: 00000000
REG_RX_ADDR_P0:
0xa returned: e7 e7 e7 e7 e7
REG_TX_ADDR:
0x10 returned: e7 e7 e7 e7 e7
REG_RX_PW_P0:
0x11 returned: 00100000
REG_FIFO_STATUS:
0x17 returned: 00010001
REG_DYNPD:
0x1c returned: 00000000
REG_FEATURE:
0x1d returned: 00000000
```
After the data has been sent (`send`), you should see the following output on the receiver terminal:
```
In HW cb
nrf24l01p_rx_handler got a message: Received packet.
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
```
## Compatibility with SI24R1 or other NRF24l01p clones
CRC and Auto-ACK should be disabled.
Use
```
nrf24l01p_disable_all_auto_ack(&nrf24l01p_0);
nrf24l01p_disable_crc(&nrf24l01p_0);
```
after `nrf24l01p_init(&nrf24l01p_0, SPI_PORT, CE_PIN, CS_PIN, IRQ_PIN) < 0)`
|