Blame view

Network/libpcap-1.9.0/pcap-tstamp.manmisc.in 7.97 KB
fee2cbd6   amoreau   ajout des librairies
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
  .\"
  .\" Copyright (c) 1987, 1988, 1989, 1990, 1991, 1992, 1994, 1995, 1996, 1997
  .\"	The Regents of the University of California.  All rights reserved.
  .\" All rights reserved.
  .\"
  .\" Redistribution and use in source and binary forms, with or without
  .\" modification, are permitted provided that: (1) source code distributions
  .\" retain the above copyright notice and this paragraph in its entirety, (2)
  .\" distributions including binary code include the above copyright notice and
  .\" this paragraph in its entirety in the documentation or other materials
  .\" provided with the distribution, and (3) all advertising materials mentioning
  .\" features or use of this software display the following acknowledgement:
  .\" ``This product includes software developed by the University of California,
  .\" Lawrence Berkeley Laboratory and its contributors.'' Neither the name of
  .\" the University nor the names of its contributors may be used to endorse
  .\" or promote products derived from this software without specific prior
  .\" written permission.
  .\" THIS SOFTWARE IS PROVIDED ``AS IS'' AND WITHOUT ANY EXPRESS OR IMPLIED
  .\" WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF
  .\" MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
  .\"
  .TH PCAP-TSTAMP @MAN_MISC_INFO@ "8 March 2015"
  .SH NAME
  pcap-tstamp \- packet time stamps in libpcap
  .SH DESCRIPTION
  When capturing traffic, each packet is given a time stamp representing,
  for incoming packets, the arrival time of the packet and, for outgoing
  packets, the transmission time of the packet.  This time is an
  approximation of the arrival or transmission time.  If it is supplied by
  the operating system running on the host on which the capture is being
  done, there are several reasons why it might not precisely represent the
  arrival or transmission time:
  .IP
  if the time stamp is applied to the packet when the networking stack
  receives the packet, the networking stack might not see the packet until
  an interrupt is delivered for the packet or a timer event causes the
  networking device driver to poll for packets, and the time stamp might
  not be applied until the packet has had some processing done by other
  code in the networking stack, so there might be a significant delay
  between the time when the last bit of the packet is received by the
  capture device and when the networking stack time-stamps the packet;
  .IP
  the timer used to generate the time stamps might have low resolution,
  for example, it might be a timer updated once per host operating system
  timer tick, with the host operating system timer ticking once every few
  milliseconds;
  .IP
  a high-resolution timer might use a counter that runs at a rate
  dependent on the processor clock speed, and that clock speed might be
  adjusted upwards or downwards over time and the timer might not be able
  to compensate for all those adjustments;
  .IP
  the host operating system's clock might be adjusted over time to match a
  time standard to which the host is being synchronized, which might be
  done by temporarily slowing down or speeding up the clock or by making a
  single adjustment;
  .IP
  different CPU cores on a multi-core or multi-processor system might be
  running at different speeds, or might not have time counters all
  synchronized, so packets time-stamped by different cores might not have
  consistent time stamps.
  .LP
  In addition, packets time-stamped by different cores might be
  time-stamped in one order and added to the queue of packets for libpcap
  to read in another order, so time stamps might not be monotonically
  increasing.
  .LP
  Some capture devices on some platforms can provide time stamps for
  packets; those time stamps are usually high-resolution time stamps, and
  are usually applied to the packet when the first or last bit of the
  packet arrives, and are thus more accurate than time stamps provided by
  the host operating system.  Those time stamps might not, however, be
  synchronized with the host operating system's clock, so that, for
  example, the time stamp of a packet might not correspond to the time
  stamp of an event on the host triggered by the arrival of that packet.
  .LP
  Depending on the capture device and the software on the host, libpcap
  might allow different types of time stamp to be used.  The
  .BR pcap_list_tstamp_types (3PCAP)
  routine provides, for a packet capture handle created by
  .BR pcap_create (3PCAP)
  but not yet activated by
  .BR pcap_activate (3PCAP),
  a list of time stamp types supported by the capture device for that
  handle.
  The list might be empty, in which case no choice of time stamp type is
  offered for that capture device.  If the list is not empty, the
  .BR pcap_set_tstamp_type (3PCAP)
  routine can be used after a
  .B pcap_create()
  call and before a
  .B pcap_activate()
  call to specify the type of time stamp to be used on the device.
  The time stamp types are listed here; the first value is the #define to
  use in code, the second value is the value returned by
  .B pcap_tstamp_type_val_to_name()
  and accepted by
  .BR pcap_tstamp_type_name_to_val() .
  .RS 5
  .TP 5
  .BR PCAP_TSTAMP_HOST " - " host
  Time stamp provided by the host on which the capture is being done.  The
  precision of this time stamp is unspecified; it might or might not be
  synchronized with the host operating system's clock.
  .TP 5
  .BR PCAP_TSTAMP_HOST_LOWPREC " - " host_lowprec
  Time stamp provided by the host on which the capture is being done.
  This is a low-precision time stamp, synchronized with the host operating
  system's clock.
  .TP 5
  .BR PCAP_TSTAMP_HOST_HIPREC " - " host_hiprec
  Time stamp provided by the host on which the capture is being done.
  This is a high-precision time stamp; it might or might not be
  synchronized with the host operating system's clock.  It might be more
  expensive to fetch than
  .BR PCAP_TSTAMP_HOST_LOWPREC .
  .TP 5
  .BR PCAP_TSTAMP_ADAPTER " - " adapter
  Time stamp provided by the network adapter on which the capture is being
  done.  This is a high-precision time stamp, synchronized with the host
  operating system's clock.
  .TP 5
  .BR PCAP_TSTAMP_ADAPTER_UNSYNCED " - " adapter_unsynced
  Time stamp provided by the network adapter on which the capture is being
  done.  This is a high-precision time stamp; it is not synchronized with
  the host operating system's clock.
  .RE
  .LP
  By default, when performing a live capture or reading from a savefile,
  time stamps are supplied as seconds since January 1, 1970, 00:00:00 UTC,
  and microseconds since that seconds value, even if higher-resolution
  time stamps are available from the capture device or in the savefile.
  If, when reading a savefile, the time stamps in the file have a higher
  resolution than one microsecond, the additional digits of resolution are
  discarded.
  .LP
  The
  .BR pcap_set_tstamp_precision (3PCAP)
  routine can be used after a
  .B pcap_create()
  call and after a
  .B pcap_activate()
  call to specify the resolution of the time stamps to get for the device.
  If the hardware or software cannot supply a higher-resolution time
  stamp, the
  .B pcap_set_tstamp_precision()
  call will fail, and the time stamps supplied after the
  .B pcap_activate()
  call will have microsecond resolution.
  .LP
  When opening a savefile, the
  .BR pcap_open_offline_with_tstamp_precision (3PCAP)
  and
  .BR pcap_fopen_offline_with_tstamp_precision (3PCAP)
  routines can be used to specify the resolution of time stamps to be read
  from the file; if the time stamps in the file have a lower resolution,
  the fraction-of-a-second portion of the time stamps will be scaled to
  the specified resolution.
  .LP
  The
  .BR pcap_get_tstamp_precision (3PCAP)
  routine returns the resolution of time stamps that will be supplied;
  when capturing packets, this does not reflect the actual precision of
  the time stamp supplied by the hardware or operating system and, when
  reading a savefile, this does not indicate the actual precision of time
  stamps in the file.
  .SH SEE ALSO
  .na
  pcap_set_tstamp_type(3PCAP),
  pcap_list_tstamp_types(3PCAP),
  pcap_tstamp_type_val_to_name(3PCAP),
  pcap_tstamp_type_name_to_val(3PCAP),
  pcap_set_tstamp_precision(3PCAP),
  pcap_open_offline_with_tstamp_precision(3PCAP),
  \%pcap_fopen_offline_with_tstamp_precision(3PCAP),
  \%pcap_get_tstamp_precision(3PCAP)
  .ad